Garion FP C-Arm

X-Ray Fluoroscopy

Description

The Garion FP C-Arm has an A-Si Flat Panel. It's motorized C-Arm movement reduces the centering time and intervention, and a high-frequency generator Power 20 kW - generating less heat for better performance.
The high-frequency generator is extremely stable and reliable.
Spectral purity of emitted X-ray is exceptional allowing to reduce the dose to the patient and operators.
All functions are automated or managed through the console by software.
Picture Archiving Communication System (PACS), WAD SYSTEM, RX complex water&air cooling system, endless fluoroscopy, and anti-collision SYSTEM for Flat panel detector.

Technical details

C-arm
Isocentric in all dimension C-Arm
Depth from the center of the FPD: 690
Focal to FPD distance variable: 920-1040
Collimator to detector working distance: 720-840
Horizontal movement: 220
Motorized vertical movement : 500
Motorized lateral inclination movement range : 360
Horizontal inclination (wig-wag) : +\- 12
Orbital rotation movement range : +45 -100(FP)
Overscanning : 10 degree
HF generator
Inverter frequency : 40 khz
Fluoroscopy : YES
Power at 100 kv : 20kW
Fluoroscopy mA : Up to 40
Fluoroscopy kV range : from 40 to 120
digital radiography mA presetted (fluorography)
(pulsed fluoroscopy high contrast) : from 40 to 200
Max fluoroscopy pulsed frequency : 25 imp/sec
At 100 kv max mA : 200
Digital display of parameters : YES
Possible programming parameters by user following prede
Ability to select low dose mode : YES
Auto dose Adjust in X-ray fluoroscopy and fluorography : YES

https://sghealthcare.com

Item condition New
Quantity
Price $0

NOTE : Once you add an item to the cart, we allow you 48 hours to buy before the item expires.

FDA   CE   https://sghealthcare.com

Specifications

Manufacturer SG Healthcare
Make Garion
Year of manufacturing 2014
Model Garion FP C-Arm
Condition New
Last used N/A

Details Technical details

C-arm
Isocentric in all dimension C-Arm
Depth from the center of the FPD: 690
Focal to FPD distance variable: 920-1040
Collimator to detector working distance: 720-840
Horizontal movement: 220
Motorized vertical movement : 500
Motorized lateral inclination movement range : 360
Horizontal inclination (wig-wag) : +\- 12
Orbital rotation movement range : +45 -100(FP)
Overscanning : 10 degree
HF generator
Inverter frequency : 40 khz
Fluoroscopy : YES
Power at 100 kv : 20kW
Fluoroscopy mA : Up to 40
Fluoroscopy kV range : from 40 to 120
digital radiography mA presetted (fluorography)
(pulsed fluoroscopy high contrast) : from 40 to 200
Max fluoroscopy pulsed frequency : 25 imp/sec
At 100 kv max mA : 200
Digital display of parameters : YES
Possible programming parameters by user following prede
Ability to select low dose mode : YES
Auto dose Adjust in X-ray fluoroscopy and fluorography : YES